Moteur de recherche d’entreprises européennes
Financement de l’UE (3 591 014 €) : IRM-DDG pour la détection du cancer - Une nouvelle approche d’imagerie médicale qui est corrélée à la TEP-FDG sans rayonnement ionisant Hor 21/11/2024 Programme de recherche et d'innovation de l'UE « Horizon »
Vue d’ensemble
Texte
IRM-DDG pour la détection du cancer - Une nouvelle approche d’imagerie médicale qui est corrélée à la TEP-FDG sans rayonnement ionisant
Positron emission tomography (PET) measurements of 2-deoxy-2-[18F]fluoro-D-glucose (FDG) uptake have been widely used clinically for tumour staging, prognosis, and treatment monitoring, where it can be more sensitive at detecting treatment response than magnetic resonance imaging (MRI) and computerised tomography (CT) -based evaluations of tumour size. 2-deoxy-D-glucose (DG) and FDG are non-metabolisable derivatives of D-glucose that get trapped in the cells of active or malignant tissues. Even though highly sensitive, the ionising radiation associated with FDG-PET limits its frequent application (typically not more than 2-3 examinations per year) and its use in populations such as children and pregnant women, who may otherwise benefit from this valuable and unique diagnostic imaging examination. As such, alternative techniques are highly demanded. The DDG-MRI project aims at providing the benefits of FDG-PET without ionising radiation. We propose an MRI-based imaging agent and technique that will provide PET-like images with MRI without ionising radiation. To this end, we will make use of 1) a novel DG analogue that is uniformly labelled with deuterons ([D8]2-deoxy-D-glucose) and 2) rapid and sensitive deuterium MRI schemes targeted at demonstrating the uptake of this agent in malignant tissues further to intravenous administration. The expected spatial resolution will exceed that of FDG-PET (~2-3 mm in plane) in a scan time of about 2 min, with a clinically acceptable and commercially relevant dose of the labelled compound. DDG-MRI is likely to be quickly adopted by medical centres as it does not require significant hardware changes, does not change the MRI suite workflow, and is expected to cost the same as a PET scan. This consortium comprises six partners (two from industry) from five countries, enthusiastic about making DDG-MRI a medical reality for cancer detection and treatment monitoring.
| Aarhus Universitet | 220 719 € |
| Cortecnet | 500 000 € |
| Danmarks Tekniske Universitet | 273 779 € |
| GE Healthcare GmbH | 0,00 € |
| GE Healthcare Ltd. | 500 013 € |
| Hadassah Medical Organization | 560 000 € |
| Universidade de Aveiro | 539 953 € |
| Universita Degli Studi Di Torino | 499 676 € |
| Universitaet ULM | 496 875 € |
https://cordis.europa.eu/project/id/101185775
Cette annonce se réfère à une date antérieure et ne reflète pas nécessairement l’état actuel.